Products
Search
Home > Products > Pulsed Fiber Laser > 1.0um Short Pulse Fi... > CoLID Series 1064nm ...
CoLID Series 1064nm Short Pulse Fiber Laser for LiDAR
Product Description:
The CoLID series 1064nm pulsed fiber laser of Connet Laser is a laser source delivering high peak power and high pulse energy. Using MOPA configuration and all- fiber optimized design, the laser can offer the high peak power and the near diffraction-limited quality output beam.
The CoLID series 1064nm pulsed fiber laser of Connet Laser employs the module package with compact and rugged design, integrated with external trigger and synchronization output monitor. It is easily deployed and maintenance-free, ensuring a long-life and cost-effective operation. The user also can adjust pulse width and repetition rate of the laser by connecting computer. It is quite suitable for system integration.
Features:
• High peak power: up to 4kW
• Average power: up to 2W
• Repetition rate adjustable: 30-500 kHz
• Pulse energy: up to 10uJ
• Excellent beam quality
Applications:
• LiDAR
• 3D scanning
• Range finding
• Target detection
• Telemetry
Specifications:
Parameter | Unit | Min | Typ. | max |
Part No. | CoLID-1064 | |||
Operating Wavelength | nm | 1059 | 1064 | 1069 |
Pulse Energy | uJ | - | - | 10 |
Peak Power | kW | - | - | 4 |
Average Power | W | - | - | 2 |
Pulse Width | ns | 1 | - | 50 |
Repetition Rate | kHz | 30 | - | 500 |
Beam Quality | M2 | <1.1 | ||
Output Polarization | Random | |||
Output Power Stability (15 min) | % | - | - | ±1.5 |
Output Power Stability1 (8h) | % | - | ±2 | ±1.3 |
Output Isolation | No | |||
Operating Temperature (standard) | °C | 0 | - | 50 |
Operating Temperature (optional) | °C | -35 | - | 65 |
Storage Temperature | °C | -40 | - | 85 |
Power Consumption2 | W | - | - | 24 |
Operating Voltage | VDC | 5.5 to 12 | ||
Trigger Mode | TTL External trigger | |||
Output Fiber Length | m | > 0.3 | ||
Output Fiber Connector | / | FC/APC or Collimator | ||
Dimensions | mm | 90x23.5 (D x H) | ||
Weight | g | < 300 |
1. The output power stability is measured under 25℃, after 30 minutes’ warm-up.
2. Power consumption is related to output power and operating conditions.
Ordering Information:
CoLID-1064--XX-YY-ZZ-FA/Col
XX: Pulse width in ns
YY: Repetition rate in kHz
ZZ: Peak power in kW
Example: CoLID-1064-02-200-04-FA
1064nm Short Nanosecond Pulse Fiber Laser module, 2ns pulse width, 200kHz repetition rate, with 4kW peak power and 10uJ single pulse energy, FC/APC connector.