Connet 2.0um (GHz) series of high power CW fiber lasers adopt the Master Oscillator Power-Amplifier (MOPA) structure to achieve the high power output. The output power can be up to 100W with the excellent output beam quality. The generally adopted pumps are the semiconductor or fiber lasers in the bands of 793nm and 1570nm. The output polarization can be linear or random. This laser is suitable for the applications of device testing, medical treatment, remote sensing, LiDAR and mid-infrared pumping, etc. with the typical operating wavelengths of 1908nm, 1940nm, 1950nm, 2004nm and 2050nm, etc.

 

The 2.0um (GHz) series of high power CW fiber lasers employ the microprocessor-based control system with stable performance and maintenance-free operation. The benchtop laser can display the output power, the temperature and other working status in real time through the LCD on the front panel, and also can provide the alarm information in time. This laser system is with clear interface and easy operation.


Features

• High output power: up to 100W

• Good beam quality

• Stable power, Reliable performance

• Optional linear polarization output

• Narrow spectral width

• All-fiber design

 

Applications

• Medical treatment 

• Mid-infrared pump source

• LiDAR

• Device testing 

• Plastic material processing

• Non-linear effect study

• Other scientific research




Main Test Data:

Parameter

Test Result

Measured wavelength

1908.159

Linewidth

<1nm

Output power

>100W

Measured output power

101.5W

Output fiber type

BD-G25/250-11FA

Output connector

End Cap

Output spectrum

Fig. 2

Dimension

19” 3U

Notice

1. Please make sure that the output end face of the end cap is free of contamination before laser operation. The bending diameter of the laser output fiber is recommended to be no smaller than 30cm.

2. Based on the optical scheme of this laser system, the seed laser will be turned on at full power with the output power of around 2W while pressing down the LASER button. Adjusting the power knob to increase the output power.

3. Please connect the water-cooling system properly.

4. As for the water-cooled laser systems, please pay attention to anti-condensation in summer and avoid leaving water to freeze in the laser systems in winter.




Product Information and Test Equipment:


Product Name

1908nm High Power CW Fiber Laser

P/N

VFLS-1908-B

Main Test Equipment

Optical Spectrum Analyzer

(YOKOGAWA AQ6375B)

Power Meter (OPHIR FL250A)




Test Environment and Power Supply:

Parameter

Specification

Power Supply

100~240VAC, 50/60Hz

Test Temperature

25

Water-cooling Temperature

20-28 (Calibration @25)

Humidity

<90%

Warm-up Time

<30mins

Water-cooling Interface Dimension

Outer Diameter 10mm

Water Flow Requirement

6L/min



Schematic Diagram of Test:


Fig. 1Schematic Diagram of Output Spectrum and Power Measurement




Measured Spectrum


Fig. 2Measured Spectrum @Output Power: 10W